OMM 350UNI

OMM 350UNI

3 ½ digit MULTIFUNCTION INSTRUMENT

The OMM 350 model series are small 3 ½ digit panel programmable instruments designed for maximum usefulness and user comfort while maintaining their fair price. Type OMM 350UNI is a multifunction instrument with the possibility of configuration for 8 different input options, easily configurable in the instrument menu. The instrument is based on a single-chip microcontroller and an A/D converter, which ensure good accuracy, stability and easy operation of the instrument.

  • 3 ½ digit programmable projection
  • multifunction input UNI  (DC, PM, RTD, T/C, DU)
  • digital filters, tare, linearization
  • size of DIN 72 x 24 mm
  • power supply 10…30 VDC/24 VAC

 

Projection
Display range
-99999…999999,single-coloured 7-segment LED
Display height
9,1 mm
Display colour
červená, zelená
Decimal point
nastavitelná v menu - pevná nebo plovoucí
Display brightness
nastavitelný v menu
Input
DC
Range
menu selectable
±20 mV
> 10 MOhm
Input 4
±60 mV
> 10 MOhm
Input 3
±1 000 mV
1,25 MOhm
Input 1
PM
Range
menu selectable
0…20 mA
< 200 mV
Input 5
4…20 mA
< 200 mV
Input 5
0…2 V
10 MOhm
Input 4
0…5 V
1,25 MOhm
Input 1
0…10 V
1,25 MOhm
Input 1
OHM
Range
menu selectable
0…100 Ohm
0…300 Ohm
0…1,5 kOhm
0…3 kOhm
0…30 kOhm
Connection
2, 3 or 4-wire
RTD
Type
menu selectable
EU > 100/500/1 000 Ohm s 3 850 ppm/°C
-50°…450°C
RU > 50 Ohm s 3 910 ppm/°C
-200°…1 100°C
RU > 100 Ohm s 3 910 ppm/°C
-200°…450°C
US > 100 Ohm s 3 920 ppm/°C
-50°…450°C
Connection
2, 3 or 4-wire
Ni
Type
menu selectable
Ni 1 000/10 000 s 5 000 ppm/°C
-50°…250°C
Ni 1 000/10 000 s 6 180 ppm/°C
-50°…250°C
Connection
2, 3 or 4-wire
Cu
Type
menu selectable
Cu 50/100 with 4 260 ppm/°C
-50°…200°C
Cu 50/100 with 4 280 ppm/°C
-200°…200°C
Connection
2-, 3-, or 4-wire
T/C
Type
selecmenu selectable
J (Fe-CuNi)
Input 3
-200°…900°C
K (NiCr-Ni)
Input 3
-200°…1 300°C
T (Cu-CuNi)
Input 4
-200°…400°C
E (NiCr-CuNi)
Input 3
-200°…690°C
B (PtRh30-PtRh6)
Input 4
300°…1 820°C
S (PtRh10-Pt)
Input 4
-50°…1 760°C
R (Pt13Rh-Pt)
Input 4
-50°…1 740°C
N (Omegalloy)
Input 3
-200°…1 300°C
L (Fe-CuNi)
Input 3
-200°…900°C
DU
Range
Configuration is performed in two steps:
1.
setting numerical value for the beginning and end of the potentiometer range
2.
slider position calibration for the beginning and end of the potentiometer runway
Potentiometer power supply
2,5 VDC/6 mA, potentiometer resistance > 500 Ohm
External inputs
Number
1 input, on contact
Functions
OFF
No function
HOLD
Stopping measurement (option: Display - Analog output - Limits)
TARA
Tare activation
Settings
Control
The device is controlled and set by four buttons on the front panel
Menu
LIGHT
contains only items necessary for basic device settings with password access
PROFI
Full device settings with password access
USER
User menu of any item, selected from LIGHT/PROFI. Access without password.
Optional functions
ZAKAZ
button has no function
TARE
Activating function Tare
NUL. TA.
Tare reset
OM Link
Company communication interface for operation, setting and update of device firmware
OM Link program is also designed for visualization and filing of meas. values from more instruments
Instrument accuracy and functionality
Temperature coefficient
50 ppm/°C
Accuracy
±0,2 % of range + 1 digit
±0,3 % of range + 1 digit (T/C)
Accuracy of cold junction measurement
±1,5°C
Rate
0,5/1,2/2,5/5/10 measur./s
Overload capacity
2x; 10x (t < 30 ms)
Resolution (RTD, T/C)
1°C, 0,1°C
Wire compensation (RTD, OHM)
< 30 Ohm
Cold junction compensation
nastavitelná -20°…99°C, automatická
Linearization
linear interpolation in 25 points (only via OM Link)
Digital filters
exponential mean
from 2…100 measurements
rounding
setting projection step for display
Functions
Tare
designed to reset display on non-zero input signal
Watch-dog
reset after 500 ms
Calibration
at 25°C and 40 % r.h.
Comparators
Type
Digital, menu adjustable, contact connect. < 50 ms
Mode
Hysteresis
switch. point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) determ. switching delay
Relay idle state
rozepnutý nebo sepnutý - nastavitelný v menu
Output
1x bistable relay (48 VAC/30 VDC, 3A)
2x bistable relay (48 VAC/30 VDC, 3A)
1x open collector (30 VDC/100 mA)
2x open collector (30 VDC/100 mA)
Power supply
Power supply
10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 45 A/1 ms, isolated
Current draw
< 2,1 W/2,2 VA
Mechanical properties
Material
Noryl GFN2 SE1, non-inflammable UL 94 V-I
Dimensions
72 x 24 x 106 mm (w x h x d)
Panel cutout
68 x 21,5 mm (w x h)
Operating conditions
Connection
connector terminal board, cable section < 1,5/2,5 mm2
Stabilization period
within 15 minutes after switch on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP42 (front panel only)
El. safety
EN 61010-1, A2
Dielectric strength
2,5 kVAC within 1 min. between pow. supply and input
4 kVAC within 1 min. between input and relay output
Insulation resistance
for polution degree II, measuring cat. III.
power supply
300 V (ZI)*
input, output
300 V (ZI), 150 V (Di)*
EMC
EN 61326-1
Seismic capacity
IEC 980: 1993, par.6
Explanatory notes

PI - Primary insulation, DI - Double insulation

Images
Connection
Dimensions and installation
To assemble the order, first select the desired instrument configuration.
OMM 350UNI-????
Power supply
Any
?
Any
?
10...30 V, izolované
0
80...250 V, izolované
1
Measuring range
Any
?
Any
?
Pt 100 / 300 Ohm
A
Pt 500 / 1500 Ohm
B
Pt 1000 / Ni 1000 / 3 KOhm
C
Ni 10 000 / 30 KOhm
D
na přání
Z
Comparators
Any
?
Any
?
ne
0
1x relé
1
2x relé
2
1x otevřený kolektor
3
2x otevřený kolektor
4
Analogový výstup
5
Display color
Any
?
Any
?
červená
1
zelená
2
Selected combination is invalid
Alternatives in stock
OMM 350UNI-0A11In stock < 5 pcs

User manuals

File nameFile typeVersionLanguageDownload
Návod OMM350
PDF
2016.1.1 csDownload
Operating instrucitons OMM350
PDF
2007.1.1 enDownload
Show all ↓Hide ↑