OMD 202UQC

OMD 202UQC

4/6  digit UNIVERSAL COUNTER

The OMD 202 model series are large programmable displays designed for indoor and outdoor use with IP64 cover.
Type OMD 202UQC is a universal 6-digit panel programmable two-channel counter/frequency meter/signal evaluation from IRC sensors, and timer/clock.  The instrument is based on a single-chip microcontroller and efficient gate array, which ensures high accuracy, stability and easy operation of the instrument.
Displays are suitable for projection of measured data in production lines and operations with legibility up to 80 m.

  • 4/6 digit programmqable projection
  • counter/frequency meter/timer/clock
  • 0,002 Hz…1 MHz; UP/DW; IRC
  • three-color LED or high bright LED
  • digit height: 57; 100; 125 mm
  • IR control
  • tare/preset/sum/math.funkctions
  • digital filters, imput filters
  • size of DIN 96 x 48 mm
  • power supply 10…30 V AC/DC or 80…250 V AC/DC

Options

  • excitation

  • comparators

  • data output

  • analog output

 

Projection
Display range
-999…9999, 3-coloured 7-segment LED
-99999…999999, 3-coloured 7-segment LED
-999…9999, single-coloured intensive LED (1200 mcd)
-99999…999999, single-coloured intensive LED (1200 mcd)
Number of characters
4 characters (only for height 100/125 mm
6 characters
Display height
57 mm, 100 mm, 125 mm
Display colour
červená, zelená, červená/zelená/oranžová
Signalizing LED
1, 2, 3, 4
Limits L1, L2, L3, L4 (red)
T
Tare (green)
M
Min./Max. value (green)
Description
poslední dva znaky displeje lze použít pro zobrazení měřených veličin (jen 6místný displejí)
Decimal point
nastavitelná v menu - pevná nebo plovoucí
Display brightness
nastavitelný v menu
Displayed values
COUNT.
Value from channel Counter
FREQ.
Value from channel Frequency
Settings
Control
The instrument is set and controlled by an IR remote control
Selected functions can also be controlled via external inputs
Menu
LIGHT
contains only items necessary for basic device settings with password access
PROFI
Full device settings with password access
USER
User menu of any item, selected from LIGHT/PROFI. Access without password.
Optional functions
Buttons "Left", "Up", "Down", "Enter" can be assigned additional optional features
ZAKAZ
button has no function
COUNT.
Viewing value - channel Counter
FREQ.
Viewing value - channel Frequency
CLEAR
Counter reset
TARE
Activating function Tare
CL. SUM.
Summation reset
SUM.
Viewing Summation
NUL. TA.
Tare reset
MENU
Direct access to the selected menu item
DOC. H.
Temporary projection of selected values
START
Start for Stopwatch/watch
PAUZA
Till the next touch the display will show the last value
CLR
Resetting Stopwatch/Watch
STOP
Stopping Stopwatch/Watch
CLR. ST.
Stopping and resetting Stopwatch/Watch
OM Link
Company communication interface for operation, setting and update of device firmware
OM Link program is also designed for visualization and filing of meas. values from more instruments
Instrument accuracy and functionality
Temperature coefficient
50 ppm/°C
Accuracy
±0,01 % of range + 1 digit (frequency)
Overload capacity
2x; 10x (t < 30 ms)
Linearization
linear interpolation in 50 points (only via OM Link)
Digital filters
arithmetic mean
from 2…100 measurements
floating mean
from 2…30 measurements
exponential mean
from 2…100 measurements
rounding
setting projection step for display
input filter
transmits input signal range 1 MHz...10 min
Functions
Min/max value
registration of min./max. value achieved during measurement
Tare
designed to reset display on non-zero input signal
Peak value
display shows only max. or min. values
Preset
initial non-zero value, which is read after each counter reset
Summation
number registration upon shift operation
Current value
single setting of the initial value
Math. functions
polynom, 1/x, logaritmus, exponenciál, odmocnina, mocnina, sin x
Time backup
Lithium cell CR 2032RV, 3V/220 mAh
Watch-dog
reset after 400 ms
Calibration
at 25°C and 40 % r.h.
Comparators
Type
Digital, menu adjustable, contact connect. < 30 ms
Mode
Hysteresis
switch. point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) determ. switching delay
From-To
output interval ON and OFF
Dose
period, its multiples and time (0 ... 99.9 s), during which the output is active
Relay idle state
rozepnutý nebo sepnutý - nastavitelný v menu
Output
1x relay, switch on contact (250 VAC/30 VDC, 3A)
2x relay, switch on contact (250 VAC/30 VDC, 3 A)
3x relay, switch on contact (250 VAC/30 VDC, 3A)
4x relay, switch on contact (250 VAC/30 VDC, 3A)
Data outputs
Protocol
ASCII, MESSBUS, MODBUS - RTU, PROFIBUS DP
Data format
8 bits + no parity + 1 stop bit (ASCII)
7 bits + even parity + 1 stop bit (Messbus)
Rate
600…230 400 Baud
0,0096…12 MBaud (PROFIBUS)
RS 232
izolovaná
RS 485
izolovaná, adresace max. 31 přístrojů
Analogue outputs
Type
Isolated, programmable with a 16-bit D / A converter, type and range are menu selectable
Nonlinearity
±0,1 % of range
Temperature coefficient
15 ppm/°C
Rate
response to value change < 1 ms
Range
0…2 V, 0…5 V, 0…10 V, ±10 V, 0…5 mA, 0…20 mA, 4…20 mA
Compensation
600 Ohm/12 V, 1 000 Ohm/24 V
Error state
at range of 4...20mA
error message indication (<3.0 mA)
Detection of current loop interruption
Sensor excitation
Adjustable
5…24 VDC/max. 1,2 W
Power supply
Power supply
10…30 V AC/DC, ±10 %, PF > 0,4, I < 45 A/1 ms, isolated
80…250 V AC/DC, ±10 %, PF > 0,4, I < 45 A/2 ms, isolated
Current draw
< 22 W/22 VA
Power supply protection
Power supply is protected by a fuse inside the instrument
Mechanical properties
Material
Anodized aluminum, black
Dimensions
57 mm/6 d.
375 x 119 x 88 mm
100 mm/4 d.
465 x 181 x 88 mm
100 mm/6 d.
651 x 181 x 88 mm
125 mm/4 d.
539 x 237 x 88 mm
125 mm/6 d.
754 x 237 x 88 mm
Panel cutout
57 mm/6 d.
367 x 111 mm
57 mm/6 d.
367 x 111 mm
100 mm/6 d.
643 x 173 mm
125 mm/4 d.
531 x 228 mm
125 mm/6 d.
746 x 228 mm
Installation
Into panel
On the wall/ceiling using bracket (included)
Operating conditions
Connection
cable bushings
connector terminal board, cable section < 1,5/2,5 mm2
Stabilization period
within 15 minutes after switch on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP64
El. safety
EN 61010-1, A2
Dielectric strength
4 kVAC within 1 min. between pow. supply and input
4 kVAC within 1 min. between pow. supply and data/anal. output
4 kVAC within 1 min. between input and relay output
2,5 kVAC within 1 min.between input and data/anal. output
Insulation resistance
for polution degree II, measuring cat. III.
power supply
670 V (ZI), 300 V (Di)*
input, output, PN
300 V (ZI), 150 V (Di)*
EMC
EN 61326-1
Input
UQC
Input
menu selectable
on contact, TTL, NPN/PNP, Line
0...60 V, comparation levels are adjustable in the menu
Input frequency
0,002 Hz…1 MHz
0,002 Hz…500 kHz (Mode QUADR and UP/DW)
Measurement mode
SINGLE
Counter/Frequency
A + B
Counter/Frequency with AND function
xNOR
Counter/Frequency with NOR function
STRIDA
Duty cycle measurement
QUADR
Counter/Frequency for IRC sensor
UP/DW
Counter/Frequency
UP - DW
Counter/Frequency
TIME
Stopwatch
RTC
Clock
Time base
0,05/1/2/3/5/10/20 s
1/2/5/10 min
Calibration coefficient
0,00001…999999
Preset
0…999999
Input filter
out
1/10/100/250/500/1 000 kHz
1/10/45/55/65/100 Hz
2/5/10 s
1/10 min
Functions
Preset
initial non-zero value, which is always read after resetting the instrument
Current value
single setting of the initial value
Summation
registration of numbers during shift operation
External inputs
Number
3 inputs, on contact
Functions
OFF
No function
HOLD
Stopping measurement (option: Display - Analog output - Limits)
TARA
Tare activation
CLEAR
Resetting display
SUMA
Sum display
CL.SUM.
Resetting sum
NUL. M.M.
Resetting Min/Max. value
Images
Dimensions and installation
Connection
To assemble the order, first select the desired instrument configuration.
OMD 202UQC-?????????-??
Power supply
Any
?
Any
?
10...30 V AC/DC
0
80...250 V AC/DC
1
Extension
Any
?
Any
?
Kontakt, TTL, NPN/PNP, úroveň: 25 mV…60 V
A
SSI vstup
B
Linkový vstup
C
Comparator
Any
?
Any
?
ne
0
1x relé
1
2x relé
2
3x relé
3
4x relé
4
Analogue output
Any
?
Any
?
ne
0
ano (500 Ohm/12 V)
1
ano (1 kOhm/24 V)
2
Data output
Any
?
Any
?
ne
0
RS 232
1
RS 485
2
MODBUS
3
PROFIBUS
4
10/100 BaseT Ethernet
7
Excitation
Any
?
Any
?
ne
0
ano
1
Digit height
Any
?
Any
?
57 mm
1
100 mm
2
125 mm
3
Number of digits
Any
?
Any
?
4 číslice (100/125 mm)
1
6 číslic
3
Colour/Type of display
Any
?
Any
?
červená (vysoce svítivé LED)
1
zelená (vysoce svítivé LED)
2
červená/zelená/oranžová (7segmentové LED)
3
specification
Any
??
Any
??
Standardní
00
ADEL-st.SW, odst. LED C/F+ LED tečky vpravo
01
ADEL- vše jako 01+ přednastavení jako denní počíta
02
Selected combination is invalid
For the selected combination there are no devices in stock

Firmware

File nameFile typeVersionLanguageDownload
OMD202UQC-4 80-003 OMD
HEX
2013 xxDownload
Show all ↓Hide ↑

Software

File nameFile typeVersionLanguageDownload
GSD OM-Profibus
ZIP
2020 xxDownload
GSDML OM-Profinet
ZIP
2020.2.33 xxDownload
Show all ↓Hide ↑

ISOLATED TRANSDUCER • USB OM INSTRUMENTS

Small compact transducer OM LINK USB with cable ensures safe and comfortable galvanically isolated connection between your computer and ORBIT MERRET instruments.