OMD 202RS

OMD 202RS

4/6 digit DATA DISPLAY

The OMD 202 model series are large programmable displays designed for indoor and outdoor use with IP64 cover.
Type OMD 202RS is a data display from serial lines RS 232/485 with protocole ASCII, MESSBUS, PROFIBUS DP and MODBUS - RTU.
The instrument is based on a single-chip microcontroller with a multichannel 24-bit sigma-delta converter, which ensures good accuracy, stability and easy operation of the instrument.
Displays are suitable for projection of measured data in production lines and operations with legibility up to 80 m.

  • 4/6 digit programmable projection
  • input: RS 232/485
  • ASCII, MESSBUS, PROFIBUS DP, MODBUS RTU
  • three-color LED or high bright LED
  • digit height: 57; 100; 125 mm
  • IR control
  • digital filters, tare, linearization
  • size of DIN 96 x 48 mm
  • power supply 10…30 V AC/DC or 80…250 V AC/DC

Options

  • excitation

  • comparators

  • analog output

 

Projection
Display range
-999…9999, 3-coloured 7-segment LED
-99999…999999, 3-coloured 7-segment LED
-999…9999, single-coloured intensive LED (1200 mcd)
-99999…999999, single-coloured intensive LED (1200 mcd)
Number of characters
4 characters (only for height 100/125 mm
6 characters
Display height
57 mm, 100 mm, 125 mm
Display colour
červená, zelená, červená/zelená/oranžová
Signalizing LED
1, 2, 3, 4
Limits L1, L2, L3, L4 (red)
T
Tare (green)
M
Min./Max. value (green)
Description
poslední dva znaky displeje lze použít pro zobrazení měřených veličin (jen 6místný displejí)
Decimal point
nastavitelná v menu - pevná nebo plovoucí
Display brightness
nastavitelný v menu
Displayed values
Kan A
Value from channel A
Fil. A
Value from channel A after digital filter adjustment
Mat. Fn.
Value of mathematical function
Max.
Maximum value
Min.
Minimum value
Settings
Control
The instrument is set and controlled by an IR remote control
Selected functions can also be controlled via external inputs
Menu
LIGHT
contains only items necessary for basic device settings with password access
PROFI
Full device settings with password access
USER
User menu of any item, selected from LIGHT/PROFI. Access without password.
Optional functions
ZAKAZ
button has no function
NUL. M.M.
Resetting Min/Max vaslues
NUL. TA.
Tare reset
MENU
Direct access to the selected menu item
DOC. H.
Temporary projection of selected values
TARA
Activating function Tare
OM Link
Company communication interface for operation, setting and update of device firmware
OM Link program is also designed for visualization and filing of meas. values from more instruments
Instrument accuracy and functionality
Temperature coefficient
50 ppm/°C
Linearization
linear interpolation in 50 points (only via OM Link)
Digital filters
arithmetic mean
from 2…100 measurements
floating mean
from 2…30 measurements
exponential mean
from 2…100 measurements
rounding
setting projection step for display
Functions
Min/max value
registration of min./max. value achieved during measurement
Tare
designed to reset display on non-zero input signal
Peak value
display shows only max. or min. values
Math. functions
polynom, 1/x, logaritmus, exponenciál, odmocnina, mocnina, sin x
Watch-dog
reset after 400 ms
Calibration
at 25°C and 40 % r.h.
Comparators
Type
Digital, menu adjustable, contact connect. < 30 ms
Mode
Hysteresis
switch. point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) determ. switching delay
From-To
output interval ON and OFF
Dose
period, its multiples and time (0 ... 99.9 s), during which the output is active
Relay idle state
rozepnutý nebo sepnutý - nastavitelný v menu
Output
1x relay, switch on contact (250 VAC/30 VDC, 3A)
2x relay, switch on contact (250 VAC/30 VDC, 3 A)
3x relay, switch on contact (250 VAC/30 VDC, 3A)
4x relay, switch on contact (250 VAC/30 VDC, 3A)
Analogue outputs
Type
Isolated, programmable with a 16-bit D / A converter, type and range are menu selectable
Nonlinearity
±0,1 % of range
Temperature coefficient
15 ppm/°C
Rate
response to value change < 1 ms
Range
0…2 V, 0…5 V, 0…10 V, ±10 V, 0…5 mA, 0…20 mA, 4…20 mA
Compensation
600 Ohm/12 V, 1 000 Ohm/24 V
Error state
at range of 4...20mA
error message indication (<3.0 mA)
Detection of current loop interruption
Sensor excitation
Adjustable
5…24 VDC/max. 1,2 W
Power supply
Power supply
10…30 V AC/DC, ±10 %, PF > 0,4, I < 45 A/1 ms, isolated
80…250 V AC/DC, ±10 %, PF > 0,4, I < 45 A/2 ms, isolated
Current draw
< 22 W/22 VA
Power supply protection
Power supply is protected by a fuse inside the instrument
Mechanical properties
Material
Anodized aluminum, black
Dimensions
57 mm/6 d.
375 x 119 x 88 mm
100 mm/4 d.
465 x 181 x 88 mm
100 mm/6 d.
651 x 181 x 88 mm
125 mm/4 d.
539 x 237 x 88 mm
125 mm/6 d.
754 x 237 x 88 mm
Panel cutout
57 mm/6 d.
367 x 111 mm
57 mm/6 d.
367 x 111 mm
100 mm/6 d.
643 x 173 mm
125 mm/4 d.
531 x 228 mm
125 mm/6 d.
746 x 228 mm
Installation
Into panel
On the wall/ceiling using bracket (included)
Operating conditions
Connection
cable bushings
connector terminal board, cable section < 1,5/2,5 mm2
Stabilization period
within 15 minutes after switch on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP64
El. safety
EN 61010-1, A2
Dielectric strength
4 kVAC within 1 min. between pow. supply and input
4 kVAC within 1 min. between pow. supply and data/anal. output
4 kVAC within 1 min. between input and relay output
2,5 kVAC within 1 min.between input and data/anal. output
Insulation resistance
for polution degree II, measuring cat. III.
power supply
670 V (ZI), 300 V (Di)*
input, output, PN
300 V (ZI), 150 V (Di)*
EMC
EN 61326-1
Input
RS
Input
fixed, according to order
RS 232/485
PROFIBUS DP
Protocol
ASCII
ASCII - Master
ASCII - Slave
ASCII - Universal
MESSBUS
MODBUS RTU
PROFIBUS DP
Format
8 bits + no parity + 1 stop bit
7 bits + even parity + 1 stop bit
Rate
300…230 400 Baud
9 600…12 MBaud (PROFIBUS)
Line termination
short circuit module socket inside the instrument
Images
Dimensions and installation
Connection
To assemble the order, first select the desired instrument configuration.
OMD 202RS-????????-??
Power supply
Any
?
Any
?
10...30 V AC/DC
0
80...250 V AC/DC
1
Extension
Any
?
Any
?
ASCII, RS 232/485
A
MODBUS
B
PROFIBUS
C
PROFINET
D
Comparator
Any
?
Any
?
ne
0
1x relé
1
2x relé
2
3x relé
3
4x relé
4
Analogue output
Any
?
Any
?
ne
0
ano (500 Ohm/12 V)
1
ano (1 kOhm/24 V)
2
Excitation
Any
?
Any
?
ne
0
ano
1
Digit height
Any
?
Any
?
57 mm
1
100 mm
2
125 mm
3
Number of digits
Any
?
Any
?
4 číslice (100/125 mm)
1
6 číslic
3
Colour/Type of display
Any
?
Any
?
červená (vysoce svítivé LED)
1
zelená (vysoce svítivé LED)
2
červená/zelená/oranžová (7segmentové LED)
3
modrá (vysoce svítivé LED)
4
specification
Any
??
Any
??
Standard
00
Centre Pesage - rozšířené nastavení RS
02
Speciál pro ADAX - 67-Fxx
03
Speciál pro s.n.o.p. dvoubarevné zobrazování
04
Komunikační protokol ELEN
05
Selected combination is invalid
Alternatives in stock
OMD 202RS-0D000133-00In stock < 5 pcs
OMD 202RS-1A000214-00In stock < 5 pcs
OMD 202RS-1A000231-00In stock < 5 pcs

Firmware

File nameFile typeVersionLanguageDownload
OMD202RS-4 67-502
HEX
2020 xxDownload
Show all ↓Hide ↑

Software

File nameFile typeVersionLanguageDownload
GSD OM-Profibus
ZIP
2020 xxDownload
GSDML OM-Profinet
ZIP
2020.2.33 xxDownload
Show all ↓Hide ↑

ISOLATED TRANSDUCER • USB OM INSTRUMENTS

Small compact transducer OM LINK USB with cable ensures safe and comfortable galvanically isolated connection between your computer and ORBIT MERRET instruments.