OM 602UQC

OM 602UQC

6 digit DUAL UNIVERSAL COUNTER

Type OM 602UQC is a universal programmable dual panel counter/frequency meter/evaluation of signals from IRC sensors, and clock/timer. The instrument is based on a single-chip microcontroller and an efficient gate array, which ensure good accuracy, stability and easy operation of the instrument.

  • 6 digit programmable projection
  • counter/frequencymeter/clock/timer
  • 0,002 Hz…1 MHz; UP/DW; IRC
  • tare/preset/sum/math.funkctions
  • digital filters, input filters
  • size of DIN 96 x 48 mm
  • power supply 10…30 V AC/DC or 80…250 V AC/DC

Options

  • excitation

  • comparators

  • data output

  • analog output

  • measured value record

 

Projection
Display range
-99999…999999, single-coloured 14-segment LED
Display height
14 mm
Display colour
červená, zelená
Signalizing LED
T
Tare (green)
M
Min./Max. value (green)
C, F, 1, 2
Channels 1, 2 - counter, frequency (orange)
Description
poslední dva znaky displeje lze použít pro zobrazení měřených veličin (jen 14 mm displej)
Decimal point
nastavitelná v menu - pevná nebo plovoucí
Display brightness
nastavitelný v menu
Displayed values
Kan C1
Value from channel 1 - Counter
Fil. C1
Value from channel 1 - Counter after digital filter adjustment
Kan F1
Value from channel 1 - Frequency
Fil. F1
Value from channel 1 - Frequency after digital filter adjustment
Kan C2
Value from channel 2 - Counter
Fil. C2
Value from channel 2 - Counter after digital filter adjustment
Fil. F2
Value from channel 2 - Frequency after digital filter adjustment
Kan F2
Value from channel 2 - Frequency
Mat. Fn.
Value of mathematical function
Max.
Maximum value
Min.
Minimum value
Settings
Control
The device is controlled and set by five buttons on the front panel
Selected functions can also be controlled via external inputs
Menu
LIGHT
contains only items necessary for basic device settings with password access
PROFI
Full device settings with password access
USER
User menu of any item, selected from LIGHT/PROFI. Access without password.
Optional functions
Buttons "Left", "Up", "Down", "Enter" can be assigned additional optional features
ZAKAZ
button has no function
NUL. C.x.
Counter reset - channel 1, 2, both
N. SUM.x.
Summation reset - channel 1, 2, both
NUL. M.M.
Resetting Min/Max vaslues
NUL. T.x
Tare reset - Channel 1, 2, both, current
MENU
Direct access to the selected menu item
DOC. H.
Temporary projection of selected values
PREP. 1
Switching channels on display
ULOZ
Starting recording of the measured data into device memory
NUL. PA.
Resetting memory of the measured data
START
Start for Stopwatch/watch
PAUZA
Till the next touch the display will show the last value
CLR
Resetting Stopwatch/Watch
STOP
Stopping Stopwatch/Watch
OM Link
Company communication interface for operation, setting and update of device firmware
OM Link program is also designed for visualization and filing of meas. values from more instruments
Instrument accuracy and functionality
Temperature coefficient
50 ppm/°C
Accuracy
±0,01 % of range + 1 digit (frequency)
Overload capacity
2x; 10x (t < 30 ms)
Linearization
linear interpolation in 50 points (only via OM Link)
Digital filters
arithmetic mean
from 2…100 measurements
floating mean
from 2…30 measurements
exponential mean
from 2…100 measurements
rounding
setting projection step for display
input filter
transmits input signal range 1 MHz...10 min
Functions
Min/max value
registration of min./max. value achieved during measurement
Tare
designed to reset display on non-zero input signal
Peak value
display shows only max. or min. values
Preset
initial non-zero value, which is read after each counter reset
Summation
number registration upon shift operation
Time backup
time is running even when the power is off (display is off either)
Current value
single setting of the initial value
Math. functions
polynom, 1/x, logaritmus, exponenciál, odmocnina, mocnina, sin x
Math. operations between inputs
sum and quotient
Data record
Measured data recording into the memory
RTC
period - 1 s…1 day, time-date-display value, < 266k data, 15 ppm/°C
FAST
40 records/s, display value, < 8k data
Not available in combination with with the data output MODBUS
Time backup
Lithium cell CR 2032RV, 3V/220 mAh
Watch-dog
reset after 400 ms
Calibration
at 25°C and 40 % r.h.
Comparators
Type
Digital, menu adjustable, contact connect. < 30 ms
Mode
Hysteresis
switch. point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) determ. switching delay
From-To
output interval ON and OFF
Dose
period, its multiples and time (0 ... 99.9 s), during which the output is active
C-Pulse
auto counter reset on the preset value
On Run
output is active while stopwatch is running
Relay idle state
rozepnutý nebo sepnutý - nastavitelný v menu
Output
1x relay, switch-over contact (250 VAC/30 VDC, 3 A)
2x relay, switch-over contact (250 VAC/30 VDC, 3 A)
1x relay, switch on contact (250 VAC/30 VDC, 3A)
2x relay, switch on contact (250 VAC/30 VDC, 3 A)
2x bistable relay (250 VAC/30 VDC, 3A)
3x relay, 2x switch on + 1x switch-over contact (250 VAC/30 VDC, 3A)
4x relay, 2x switch on + 2x switch-over contact (250 VAC/30 VDC, 3A)
2x open collector (30 VDC/100 mA)
4x open collector (30 VDC/100 mA)
2x open collector (30 VDC/100 mA) + 2x relay, CO contact (250 VAC/30 VDC, 3 A)
2x SSR (250 VAC/1 A)
Data outputs
Protocol
ASCII, MESSBUS, MODBUS - RTU, PROFIBUS DP
Data format
8 bits + no parity + 1 stop bit (ASCII)
7 bits + even parity + 1 stop bit (Messbus)
Rate
600…230 400 Baud
0,0096…12 MBaud (PROFIBUS)
RS 232
izolovaná
RS 485
izolovaná, adresace max. 31 přístrojů
Analogue outputs
Type
Isolated, programmable with a 16-bit D / A converter, type and range are menu selectable
Nonlinearity
±0,1 % of range
Temperature coefficient
15 ppm/°C
Rate
response to value change < 1 ms
Range
0…2 V, 0…5 V, 0…10 V, ±10 V, 0…5 mA, 0…20 mA, 4…20 mA
Compensation
600 Ohm/12 V, 1 000 Ohm/24 V
Error state
at range of 4...20mA
error message indication (<3.0 mA)
Detection of current loop interruption
Sensor excitation
Adjustable
5…24 VDC/max. 1,2 W
Power supply
Power supply
10…30 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
80…250 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
Current draw
< 8,0 W/7,8 VA
Power supply protection
Power supply is protected by a fuse inside the instrument
Mechanical properties
Material
Noryl GFN2 SE1, non-inflammable UL 94 V-I
Dimensions
96 x 48 x 120 mm (w x h x d)
Panel cutout
90,5 x 45 mm (w x h)
Operating conditions
Connection
connector terminal board, cable section < 1,5/2,5 mm2
Stabilization period
within 15 minutes after switch on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP64 (front panel only)
El. safety
EN 61010-1, A2
Dielectric strength
4 kVAC within 1 min. between pow. supply and input
4 kVAC within 1 min. between pow. supply and data/anal. output
4 kVAC within 1 min. between input and relay output
2,5 kVAC within 1 min.between input and data/anal. output
Insulation resistance
for polution degree II, measuring cat. III.
power supply
670 V (ZI), 300 V (Di)*
input, output, PN
300 V (ZI), 150 V (Di)*
EMC
EN 61326-1
Seismic capacity
IEC 980: 1993, par.6
Input
UQC
Input
2 independent inputs, menu selectable
on contact, TTL, NPN/PNP, Line
0...60 V, comparation levels are adjustable in the menu
Input frequency
0,002 Hz…1 MHz
0,002 Hz…100 kHz (Mode STRIDA)
0,002 Hz…500 kHz (Mode QUADR and UP/DW)
Measurement mode
SINGLE
Counter/Frequency
A + B
Counter/Frequency with AND function
xNOR
Counter/Frequency with NOR function
STRIDA
Duty cycle measurement
QUADR
Counter/Frequency for IRC sensor
UP/DW
Counter/Frequency
UP - DW
Counter/Frequency
TIME
Stopwatch
RTC
Clock
Time base
0,05/1/2/3/5/10/20 s
1/2/5/10 min
Calibration coefficient
0,00001…999999
Preset
0…999999
Input filter
out
1/10/100/250/500/1 000 kHz
1/10/45/55/65/100 Hz
2/5/10 s
1/10 min
Functions
Preset
initial non-zero value, which is always read after resetting the instrument
Current value
single setting of the initial value
Summation
registration of numbers during shift operation
Time backup
time is running even when the device is off (the display is off either)
External inputs
Number
3 inputs, on contact
Functions
OFF
No function
HOLD
Stopping measurement (option: Display - Analog output - Limits)
BLOK.K.
Blocking front panel keys
B.HESL.
Blocking access to the LIGHT/PROFI menu
TARA x
Tare activation - Channel 1, 2, All, Current
Suma x
Sum display - channel 1, 2
N.SUM. x
Resetting sum - channel 1, 2, both
NUL. T.x
Resetting tare - 1, 2, All, Current
NUL. M.M.
Resetting Min/Max. value
ULOZ
Data record activation (extention of RTC/FAST)
PREP.
Gradual or BCD switching of the channels
Explanatory notes

PI - Primary insulation, DI - Double insulation

Images
Connection
Dimensions and installation
To assemble the order, first select the desired instrument configuration.
OM 602UQC-?????????-??
Power supply
Any
?
Any
?
10...30 V AC/DC
0
80...250 V AC/DC
1
Measuring range
Any
?
Any
?
Standard
A
SSI
B
Linkový
C
Comparators
Any
?
Any
?
ne
0
1x relé (spínací)
1
2x relé (spínací)
2
2x relé (spínací) + 1x relé (přepínací)
3
2x relé (spínací) + 2x relé (přepínací)
4
2x otevřený kolektor
5
4x otevřený kolektor
6
2x otevřený kolektor + 2x relé (přepínací)
7
2x relé (přepínací)
8
2x SSR
9
2x bistabilní relé
A
1x relé (přepínací)
B
Data output
Any
?
Any
?
žádný
0
RS 232
1
RS 485
2
MODBUS
3
PROFIBUS
4
10/100Tbase Ethernet
7
Analogue output
Any
?
Any
?
ne
0
ano (500 Ohm/12 V)
1
ano (1 kOhm/24 V)
2
Time backup
Any
?
Any
?
ne
0
ano
1
Excitation
Any
?
Any
?
ne
0
ano
1
Data recording
Any
?
Any
?
ne
0
RTC
1
FAST
2
Display color
Any
?
Any
?
červená
1
zelená
2
červená/zelená (20mm)
3
specification
Any
??
Any
??
Standard
00
Speciál pro Kornfeil - 78-D50
02
Speciál pro AL INVEST Břidličná A.s.
03
Selected combination is invalid
Alternatives in stock
OM 602UQC-0A2300101-00In stock < 5 pcs
OM 602UQC-1A0000101-00In stock 5 - 10 pcs
OM 602UQC-1A0010101-00In stock < 5 pcs
OM 602UQC-1A2000101-00In stock < 5 pcs
OM 602UQC-1A2200111-00In stock < 5 pcs
OM 602UQC-1A4000111-00In stock < 5 pcs

Firmware

File nameFile typeVersionLanguageDownload
OM 602UQC 78-601
HEX
2018 xxDownload
Show all ↓Hide ↑

Software

File nameFile typeVersionLanguageDownload
GSD OM-Profibus
ZIP
2020 xxDownload
GSDML OM-Profinet
ZIP
2020.2.33 xxDownload
Show all ↓Hide ↑

CAD

File nameFile typeVersionLanguageDownload
OM Krabicka
DWG
2014 xxDownload
Show all ↓Hide ↑

ISOLATED TRANSDUCER • USB OM INSTRUMENTS

Small compact transducer OM LINK USB with cable ensures safe and comfortable galvanically isolated connection between your computer and ORBIT MERRET instruments.