OM 602UQC
The OM 601UQC is a universal 6 digit panel programmable impulse counter/frequency meter/repeat/ evaluation of signals from IRC sensors and stopwatch/clock.
The instrument is based on an 8-bit microcontroller with logic array, which secures high accuracy, stability and easy operation of the instrument.
Technical data
| Measured unit | Counter (Pulses) Frequency Stop watch / Timer Time |
||||||||||
| Measuring range |
|
||||||||||
| Expansion |
|
||||||||||
| Number of inputs | 2 | ||||||||||
| Temperature coeficient | 50 ppm/°C | ||||||||||
| Accuracy | ±0,01% of the value + digit (for frequency - depends on selected time of measuring) | ||||||||||
| Type of input | Upon contact, TTL, NPN/PNP with the posibility to set the comparative levels in the instrument's menu:
|
||||||||||
| Mode |
|
||||||||||
| Presetting | -99999…999999 Initial non-zero value which is set each time when the instruemnt is re-set |
||||||||||
| Calibration constant | -0,00001…999999 Multiplication constant used to convert the number of pulses do desired projection value |
||||||||||
| Filtration constant | 0 / 10 / 20 / 45 / 55 / 65 / 100 / 200 / 500 / 1 000 / 2 000 Hz Used to filter out interfering signals (pollution). Entered value sets the maximum possible frequency the instrument can process without limitations. |
||||||||||
| Time base | 0,05 / 0,5 / 1 / 2 / 5 / 10 / 20 / 50 sekund per request: 100 / 200 / 500 seconds |
||||||||||
| Calibration | at 25°C and 40% r.h. |
| Projection range | -99999…999999 Time formats 10/24/60 ranges separated by dots |
| Type of sign projection | 14-segment LED |
| Number of signs | 6 |
| Digit height | 14 mm |
| Display color | Red Green |
| Decimal point | Selectable in the menu or floating |
| Brightness | Selectable in the menu |
| Measuring units | Last two symbols can be used to display units relating to the measured value |
| Instrument configuration | The instrument contains two independ channels (input values, state of counter / input frequency A / B), which can further be filtered and used for mathematical operations. | ||||
| Input filter | The instrument has the capability of filtering polluting elements out of the input signal ant reduce "false signals". Filtration is done by the method of sampling. |
||||
| Digital filters | Exponential average: from 2 .. 100 measurements N-th value: 2 .. 100 Radius of insensitivity: band of suppression of change of the measured value Rounding: setting the projection step for display |
||||
| Mathematic functions | Mathematical operations between channels A and B: +, -, *, /, (A-B)/B Polynomial, Inversion polynomial, Logarithm |
||||
| Maximum and minimum | The channel of min. and max. receives both min. and max. values either from the instrument's power-on, or from its re-set until the next re-set. The min and max values can be used to control peripherals. | ||||
| Tare | Zeroing the display at non-zero input signal | ||||
| Other functions | Summation: Used in production shift environment. When the display is zeroed, the count from the last shift is added to the previous counts. | ||||
| Data backup | In the event of a power failure the data is stored into an EEPROM memory. | ||||
| Time backup | Time back up (for mode Stopwatch (timer) /Clock) | ||||
| External control |
|
||||
| Number of inputs of external control | 1 | ||||
| Watch-dog | Reset after 1,2 s |
| Type of comparator | Digital, settable in the menu with parameters - Hysteresis / from - to/ Batch, mode switch on/switch off |
| Limit | -99999…999999 |
| Hysteresis | 0…999999 |
| Delay in switching | 0…99,9 s |
| Maximum response delay | 30 ms |
| Number and type of outputs | 1x relay, switch-on (250 VAC/30 VDC, 3 A) 2x relay, switch-on (250 VAC/30 VDC, 3 A) 2x relay, switch-on + 1x relay, switching (250 VAC/30 VDC, 3 A) 2x relay, switch-on + 2x relay, switching (250 VAC/30 VDC, 3 A) 2x open collector NPN (30 VDC, 0,1 A) 4x open collector NPN (30 VDC, 0,1 A) 2x open collector NPN (30 VDC, 0,1 A) + 2x relay, switching (250 VAC/30 VDC, 3 A) 2x relay, switching (250 VAC/30 VDC, 3 A) 2x SSR (250 VAC, 1 A) 2x bistabile relay (250 VAC, 3 A/250 VDC, 0,4 A) 1x relay, switching (250 VAC/30 VDC, 3 A) |
| DATA OUTPUT | RS 232 RS 485 MODBUS RTU PROFIBUS DP |
| Protocol | ASCII / DIN MESSBUS / MODBUS RTU / PROFIBUS |
| Data format | 8 bit, no parity, 1 stop bit (ASCII) 7 bit, even parity, 1 stop bit (DIN Mess-Bus) |
| Rate | 600 / 1 200 / 2 400 / 4 800 / 9 600 / 19 200 / 38 400 / 57 600 / 115 200 / 230 400 Baud 9 600…12 000 kBaud (PROFIBUS) |
| ANALOGUE OUTPUT | Programable with maximum resolution of 10.000 points. Analogue output is isolated and relates either to the display value, or to the measured value. Type and range are selectable in the programming mode. • compensation < 500 Ω/12 V • compensation < 1 000 Ω/24 V |
| Non-linearity | ±0,2% of the range |
| Temperature coeficient | 50 ppm/°C |
| Rate (maximum response delay) | 150 ms |
| Range | {0…2 V / 0…5 V / 0…10 V / 0…5 mA / 0…20 mA / 4…20 mA (with error signalling I = 3 mA) |
| Compensation of conduct max to | 500 Ohm, 1 000 Ohm, |
| AUXILIARY VOLTAGE | galvanically separated, setable by trimmer |
| Setting range | 5…24 V |
| Tolerable load | 1,2 W |
| Type of memory | Real Time - recording of measured values each with time and date stamp - data logger |
| Capacity | max. 250 000 values (RealTime) max. 8 000 values (Fast) |
| POWER SUPPLY | 24VAC ±10% 50/60Hz 230VAC ±10% 50/60Hz |
| Maximum consumption | 13,5 VA |
| Protection | Internal fuse. T630mA (DC) T160mA (AC) |
| Material | Noryl GFN2 SE1, incombustible UL 94 V-I, black |
| Dimensions | 96 x 48 x 120 mm |
| Panel cutout | 90,5 x 45 mm |
| Connection | Screw connector terminal, cross section < 2,5 mm2 | |
| Settling time | 15 minutes after switch-on | |
| Working temperature | 0…60°C | |
| Storage temperature | -10…85°C | |
| Cover | IP65 (front panel only) | |
| El. safety | ČSN EN 61010-1, A2 | |
| Dielectric strength | 4 kVAC for 1 min. between power supply and input 4 kVAC for 1 min. between power supply and data/analogue output 4 kVAC for 1 min. between input and relay output 2,5 kVAC for 1 min. between input and data/analogue output |
|
| Insulation resistance | for pollution degree II, masuring cat. III. AC power supply > 600 V (SI), 300 V (DI) DC power supply, input/output, excitation > 300 V (SI), 150 (DI)
|
|
| EMC | ČSN EN 61326-1 | |
| Seismic compatibility | ČSN EN 980: 1993, čl. 6 |